Fedders FV95A054 Freezer User Manual


 
10
C
C
A
B
A
B
A
B
Upflow Installation
The combustion air and exhaust vent may exit through
the top, left or right side of the cabinet when viewed in
the upflow position. The inducer is installed so that the
exhaust vent may exit the top and left sides without
requiring rotation.
I
f exhaust vent exits the top panel, use the two street
elbows to route the vent. One elbow secured to the
inducer drain connector, will angle toward the front of
cabinet with the second nested inside directed towards
the top panel. (The 108,000 BTUH will require an
extension between the inducer and the first elbow that
is not provided.)
If exhaust vent exits the left-side panel the pipe can be
routed straight outside the cabinet.
If exhaust vent
exists the right-side panel the inducer requires
rotation.
The exhaust vent pipe exiting the cabinet in any
installation should be long enough to install the vent
clamp on the outside of the cabinet.
COMBUSTION AIR
EXHAUST VENT
CONDENSATE DRAIN
A
B
C