OPTIONAL RAIN SHIELD INSTALLATION INSTRUCTIONS:
As an optional accessory to the Type C Draft Inducer, a rain shield has been provided to further prevent water from wind
driven rain from entering the chimney. To install please follow the instructions below.
1. Remove cap on Type C unit by removing the four mounting screws as shown in figure 1.
2. Apply a bead of the provided silicone sealant along the edges of the first three sections. (See Figure 2)
3. Then using the provided #8x3/8 screws, join the three sections by screwing each section together at the first 3 holes.
(See Figure 3)
4. Apply a bead of silicone sealant around the top of the unit at the approximate position shown in Figure 4.
5. Center the assemble three sections of the rain shield over the Type C unit so that the opening allows for the electrical
box as shown in Figure 5.
6. Apply two strips of silicone sealant the the edges of the assembled section to seal the fourth section. (See Figure 6)
7. Insert fourth section under electrical box and on top of the assembled three sections. Using the remaining #8x3/8
screws, complete the four piece assembly. (See Figure 7)
8. Using the #10x5/8 self drilling screws provided, mount the shield to the Type C unit using the two holes at the top of
each section. (See Figure 8)
9. Re-attach the cap of the Type C unit. (See Figure 9)
PN 04052900 Rev C 10/06