Fisher & Paykel CG604 Cooktop User Manual


 
18
Using your cooktop
Gas burners
The knob (Fig. 14) controls the flow of gas through the safety valve.
O
= closed valve
= maximum flow
= minimum flow
You can choose to cook at any heat between and , but never between and
O
.
Using the burners
1
Choose the control knob for the burner you want to use.
2
Press the knob down gently and turn it anticlockwise to the position. The ignitors on all the
burners will spark. Flame failure models only: Hold down the knob for approximately 10 seconds
after the burner has lit. Releasing the knob too soon will extinguish the flame.
3
Adjust the flame anywhere between the and positions. Do not adjust the flame between
and
O
.
Note: If the burner does not light within 15 seconds, turn the control knob off and wait at least
one minute before trying again.
4
After use, always turn the knobs to the off (o) position. For models without the flame failure
safety feature, you should also close the cock valve on the gas bottle or the main gas supply line.
Fig. 14a Burner knob and symbols
(CG604 models (no flame failure))
Fig. 14b Burner knob and symbols
(CG604 models (with flame failure))
Fig. 14c Burner knob and symbols
(CG905 models)