SETTING THE BURNER MINIMUM (Valves may vary)
When switching from one type of gas to another, the minimum flow rate must also be
correct: the flame should not go out even when passing suddenly from maximum to
minimum flame.
To regulate the flame follow the instructions below:
Rapid and triple ring burners
Light the burner
Set the gas valve to
LO
position
Remove the knob
With a thin screwdriver, turn the regulation screw until adjustment is correct (Fig. 2.7a
or 2.7b). On some valves, you need to pass by the hole of the microswitch (Fig. 2.7a)
to turn the regulation screw.
Inside crown of DUAL burner
Light the DUAL burner
Set the gas valve to
SIM
position
Remove the knob
– Using a screwdriver turn the screw H until the correct setting is obtained (fig. 2.8).
Outside crowns of DUAL burner
Light the DUAL burner
Set the gas valve to
LO
position
Remove the knob
– Using a screwdriver turn the screw G until the correct setting is obtained (fig. 2.8).
For LP/PROPANE gas, tighten the regulation screws completely.
2
Fig. 2.7a
Regulation screw
regulation screw
OR