Five Star Ranges TN537-7W Range User Manual


 
Installation Instructions
BEFORE YOU BEGIN
CAUTION:
Read these instructions completely and
carefully.
THESE RANGES SHOULD BE INSTALLED IN
CONJUNCTION WITH A SUITABLE
OVERHEAD VENT HOOD. Due to the high heat
capacity of this unit, particular attention should be paid to the hood
IMPORTANT - Save these instructions for local
duct work installation to assure it meets local building codes.
inspector's use.
IMPORTANT - Observe all governing codes and
Standard countertop installations:
ordinances.
A 1200 CFM hood is recommended for 48" & 60" ranges.
A 600 CFM hood is recommended for 30" & 36" ranges.
Note to Installer - Be sure to leave these instructions
with the Consumer.
Hoods should be 24" min. deep and at least the same width as the
cooktop. FiveStar hoods may be installed from 24” to 30” above the
Note to Consumer - Keep these instructions for future
cooking surface. A minimum of 28” is required when a FiveStar
reference.
Backsplash with warming shelves is used.
FiveStar recommends this product be installed by a
Check local building codes for the proper method of gas range
licensed professional.
installation. Local codes vary. Installation, electrical connections and
grounding must comply with applicable codes. In the absence of local
Product failure due to improper installation is not covered
codes, the gas range should be installed in accordance with the
under the Warranty.
National Fuel Gas Code ANSI 223.1, latest edition and National
Electrical Code ANSI/NFPA 70, latest edition.
WARNING:
This appliance must be properly grounded.
CAUTION:
In the Commonwealth of Massachusetts:
These ranges weigh up to 510 pounds. Some
This product must be installed by a licensed plumber or
gas
disassembly will reduce the weight considerable. Due to
fitter.
the weight and size of the range and to reduce the risk of
personal injury or damage to the produce and/or damage
When using ball type gas shut-off valves, they shall be T
to the floor, TWO PEOPLE ARE REQUIRE FOR PROPER
handle type.
INSTALLATION.
A flexible gas connector, when used, must not exceed
Three (3) feet.