IT is mandatory to earth the appliance:
If the appliance is directly connected to the mains electricity, an omnipolar switch
with contact gap of at least 3 mm - able to withstand the oven's power output -
must be installed between the oven and power socket.
The earth wire must by no means be interrupted by the omnipolar switch.
Always ensure that the oven is disconnected from the power supply before effecting
maintenance work and/or adjustments.
The oven may be supplied without a plug fitted on the power cord. If this occurs, choose
a plug that can withstand the oven's maximum power output. Make sure that the earth
wire (yellow/green) is properly connected to the relative plug pin.
Follow the steps below when connecting or replacing the power cable:
Disconnect the appliance or the power supply.
Open the terminal board cover.
Connect the ends of the power cable - remember that the earth wire is identified by
the yellow/green jacket. If using a BS 1363-approved 13 A plug, apply a 13 A fuse.
The power cable must be secured by the cable clamp on the terminal board to
prevent it from turning and/or detaching. No point of the cable must be exposed to
temperatures exceeding 75 °C.
The plug connecting the appliance to the mains electricity must be suitable for the
oven's power output. Moreover, the plug must be easily accessible once the oven
has been installed. An omnipolar switch with a contact gap of at least 3 mm must
be installed in the event of a direct connection to the mains electricity.
morsettiera
terminal board
bloccacavo
cable clamp
terra
earth