Foster 7322 240 Cooktop User Manual


 
26
ELECTRICAL CONN
ECTION
Th
e
installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly to the fact of the normative regulations and
which respects them scrupulously.
Protection against the parts under tension must be ensured after the building-in.
The data of connection necessary are on the stickers place on the hob casing near the
connection box.
The connection to the main must be made using an earthed plug or via an omnipolar
circuit breaking device with a contact opening of at least 3 mm.
The electrical circuit must be separated from the network by adapted devices, for
example: circuit breakers, fuses or contactors.
Caution !
This appliance has only to be connected to a network 230 V~ 50/60 Hz
Connect always the earth wire.
Respect the connection diagram.
Use the connecting cable that is attached to the device.
The green / yellow wire correspond to the earth wire, the blue wire correspond neutral wire and
the brown wire correspond to the phase.
* calculated with the simultaneous factor following standard EN 60 335-2-6/1990
Caution! Ensure that you correctly attach the wires and the bridges and tighten the
screws properly.
Mains Connection Cable diameter Cable Protection calibre
230V~
50/60Hz
1 Phase
+ N 3 x 1,5 mm
2
H 05 VV - F
H 05 RR - F
16 A
*
We
cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.