Foster FHG 2L Refrigerator User Manual


 
7
35 c9 Enable autostart with PD operation flag 0 0 0
36 c10 Select Pd by time or pressure flag 0 0 0
37 c11 Delayed compressor delay sec 4 4 4
38 d0 Type of defrost flag 0 1 1
39 dI Interval between defrosts hours 8 6 6
40 dt1 End defrost temperature, evaporator. °C/°F 4.0 20.0 20.0
41 dt2 End defrost temperature, aux. evaporator °C/°F 4.0 4.0 4.0
42 dp1 Maximum defrost duration, evaporator min 30 20 20
43 dp2 Maximum defrost duration, aux. Evaporator min 30 30 30
44 d3 Defrost start delay min 0 0 0
45 d4 Enable defrost at start up flag 0 0 0
46 d5 Defrost delay at start up min 0 0 0
47 d6 Display off during defrost - 1 1 1
48 dd Dripping time after defrost min 2 1 1
49 d8 Bypass alarm after defrost hours 1 1 1
50 d9 Defrost priority over compressor protection flag 0 0 0
51 d/1 Display defrost probe °C/°F - - -
52 d/2 Display defrost probe °C/°F - - -
53 dC Base time for defrost flag 0 0 0
54 d10 Compressor running time hours 0 0 0
55 d11 Running time temperature threshold °C/°F 1.0 1.0 1.0
56 d12 Advanced defrost - 0 0 0
57 dn Nominal defrost time - 65 65 65
58 dH Proportional factor for variation in ‘dI’ - 50 50 50
59 A0 Alarm and fan differential °C/°F 2.0 4.0 4.0
60 A1 Type of threshold for ‘AL’ and ‘AH’ flag 0 0 0
61 AL Low temperature alarm threshold °C/°F 0.0 0.0 0.0
62 AH High temperature alarm threshold °C/°F 0.0 0.0 0.0
63 Ad Low and high temperature alarm delay min 120 120 120
64 A4 Configuration of digital input 1 - 0 0 0
65 A5 Configuration of digital input 2 - 0 0 0
66 A6 Stop compressor from external alarm min 0 0 0
67 A7 External alarm detection delay min 0 0 0
68 A8 Enable alarms ‘Ed1’ and Ed2’ flag 0 0 0
69 Ado Door switch light management mode flag 0 0 0
70 Ac High condenser temperature alarm °C/°F 70.0 70.0 70.0
71 AE High condenser alarm temperature differential °C/°F 5.0 5.0 5.0
72 Acd High condenser temperature alarm delay min 0 0 0
73 AF Off time with light sensor sec 0 0 0
74 F0 Fan management flag 0 0 0
75 F1 Fan start temperature °C/°F 5.0 5.0 5.0
76 F2 Fan off with compressor off flag 1 0 0
77 F3 Fans in defrost flag 1 1 1
78 Fd Fans off after dripping min 1 1 1
79 H0 Serial address - 1 30 30
80 H1 Function of relay 4 flag 1 2 2
81 H2 Disable key / infra red flag 1 1 1
82 H3 Remote control enabling code - 0 0 0
83 H4 Disable buzzer flag 0 0 0
84 H5 Function of relay 5 - 3 3 3
85 H6 Lock out buttons - 0 0 0
86 H7 Select PD by time or pressure flag 0 0 0
87 HPr Print profile - 0 0 0
Note: The total number of parameters is 105. For ease of set up Foster only use the ones listed. The
remaining are not used and adjustment is not recommended.