Mounting the hood body
• Before attaching the hood body, tighten the two screws Vr lo-
cated on the hood body mounting points.
Hook the hood body onto the screws 12a.
Fully tighten support screws 12a.
• Adjust screws Vr to level the hood body.
12a
Vr
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120mm, the
choice of which is left to the installer.
To install a ø 150
To install the dumper 10
Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
To install a ø 120
• To install a ø 120 mm air exhaust connection, insert the re-
ducer flange 9 on the dumper 10.
Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
Remove any activated charcoal filters.
9
ø 120ø 150
10
10