19
Mounting the hood body
• Before hooking up the hood body, adjust the two screws Vr
located on the hood body connection points so that they are at
the half way point.
• Hook the hood body to the mounted bracket.
• Adjust the screws Vr to level the hood body.
• Tighten the lock screw Vf.
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert the re-
ducer flange 9 on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove any activated charcoal filters.
RECIRCULATION VERSION AIR OUTLET
• Push fit connection 15 onto the hood body outlet.
• Insert the connection extension pieces laterally 14.1 in connec-
tion 15.
• Make sure that the outlet of the extension pieces 14.1 is hori-
zontally and vertically aligned with the chimney outlets. If this
is not the case, adjust the position by either reversing the con-
nection extension pieces 14.1 and then reassemble as described
previously.
• Ensure that the activated charcoal filters have been inserted.