Franke Consumer Products FDC 902 Ventilation Hood User Manual


 
EN
1
9
19
Mounting the hood body
Before hooking up the hood body, adjust the two screws Vr
located on the hood body connection points so that they are at
the half way point.
Hook the hood body to the mounted bracket.
Adjust the screws Vr to level the hood body.
Tighten the lock screw Vf.
Vf
Vr
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
To install a ø 120 mm air exhaust connection, insert the re-
ducer flange 9 on the hood body outlet.
Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
Remove any activated charcoal filters.
ø 120ø 150
9
RECIRCULATION VERSION AIR OUTLET
Push fit connection 15 onto the hood body outlet.
Insert the connection extension pieces laterally 14.1 in connec-
tion 15.
Make sure that the outlet of the extension pieces 14.1 is hori-
zontally and vertically aligned with the chimney outlets. If this
is not the case, adjust the position by either reversing the con-
nection extension pieces 14.1 and then reassemble as described
previously.
• Ensure that the activated charcoal filters have been inserted.
15
14.1