Recirculation version air outlet
• Fix the connection 15 to the frame using the 4
screws provided.
• Fix the flange 10 to the lower opening of the connec-
tion 15.
• Connect the hood air outlet to the flange in the lower
part of the junction using a rigid or flexible ø 150
tube (by installer’s choice).
15
10
Flue assembly - Mounting the hood body
• Position the upper chimney section and fix the upper
part to the frame using the 2 screws 12c (2,9 x 6,5)
provided.
• Similarly, position the lower chimney section and
fix the lower part to the frame using the 2 screws 12c
(2,9 x 6,5) provided.
Before fixing the hood body to the frame:
• Remove the grease filters from the hood body.
• Remove any activated charcoal filters.
• From below, use the 4 screws 12f (M6 x
10)provided to fix the hood body to the frame.
12f
12c
12c