Mounting the hood body
Screw the two screws 12d supplied onto the brackets 7.1.
Hook the hood body onto the bracket 7.1, centring it around
the vertical line.
Use the adjusting screws 12d underneath the hood to level the
hood body.
7.1
12.d
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
To install a ø 120 mm air exhaust connection, insert the re-
ducer flange 9 on the hood body outlet.
Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
Remove any activated charcoal filters.
ø 120ø 150
9
RECIRCULATION VERSION AIR OUTLET
Push fit the air outlet fitting 15 onto the air outlet of the hood
body.
• Ensure that the activated charcoal filters have been inserted.
15