ELECTRICAL CONNECTION
• Remove the cover from the Field Wiring Compartment with a
phillips screwdriver.
• Feed the Power Supply Cable through the electrical knockout.
Connect the Power Supply Cable to the range- hood cable. At-
tach the Power Supply Cable grounding lead to the green screw
provided. Attach the White lead of the power supply to the
White lead of the rangehood with a twist-on type wire connec-
tor. Attach the Black lead of the power supply to the Black
lead of the rangehood with a twist-on type wire connector.
Replace the cover.
Chimney assembly
Connect the angle iron 17 to the slots in the hood canopy, open-
ing out the two side flaps slightly.
Upper exhaust chimney
Open out the two side flaps slightly, connect them behind the
Brackets 7.2.1 and close them up again until they touch.
Fix to the sides of the Brackets using 4 Screws 12c provided.
Make sure that the outlet from the Connector Extensions corre-
sponds with the Chimney outlets.
Lower exhaust chimney
Insert the Chimney into the space between the Hood Canopy
and the Angle Iron 17.
Open out the two side flaps of the Chimney slightly, connect
them between the Upper chimney and the wall and close them
up again until they touch.
Fix the bottom part to the Hood Canopy and the Angle Iron at
the sides, using the 2 Screws 12c provided.
17
1
12c
12c
12c
2.1
2.2
2
7.2.1
Power supply cable
Green
Ground
screw
Ground wire