MAINTENANCE
Grease filters
CLEANING METAL SELF- SUPPORTING GREASE FILTERS
• The filters must be cleaned every 2 months of opera-
tion, or more frequently for particularly heavy usage,
and can be washed in a dishwasher.
• Remove the filters one at a time holding them up
with one hand and pulling the handle downwards
with the other hand at the same time.
Wash the filters, taking care not to bend them. Allow
them to dry before refitting.
• When refitting the filters, make sure that the handle
is visible on the outside.
Activated charcoal filter (Recirculation version)
REPLACING THE ACTIVATED CHARCOAL FILTER
The filter is not washable and cannot be regener-
ated, and must be replaced approximately every 4
months of operation, or more frequently for par-
ticularly heavy usage.
Remove the metal grease filters
Remove the saturated activated carbon filter by
releasing the fixing hooks
Fit the new filter by hooking it into its seating
Replace the metal grease filters.
Lighting
LIGHT REPLACEMENT
20 W halogen light.
• Remove the snap-on lamp cover by levering it from
under the metal ring, supporting it with one hand.
• Remove the halogen lamp from the lamp holder by
pulling gently.
• Replace the lamp with a new one of the same type,
making sure that you insert the two pins properly into
the housings on the lamp holder.