Franke Consumer Products FNE 368 TC W Ventilation Hood User Manual


 
EN
1
3
13
Charcoal filter (ductless version)
This filter cannot be washed or regenerated. It must be replaced when the C appears on the
display or at least once every 4 months. The filter saturation alarm has to be activated already
before.
Activation of the alarm signal
In the recycling version hoods the filter saturation alarm must be activated during the instal-
lation or later.
Switch off the hood and the lights.
• Press the E-key for about 5 seconds until the last two segments of the motor LEDS are lit on
the display.
By releasing the E-key the clock icon starts to flash.
• Within 3 seconds press the D-key to activate/deactivate charcoal filter saturation alarm.
C-symbol lit - charcoal filter saturation alarm ACTIVATED.
C-symbol unlit - charcoal filter saturation alarm DEACTIVATED.
SUBSTITUTION OF THE CHARCOAL FILTER
Alarm reset
Switch off the motor and the lighting system.
• Press the G-key for at least 2 seconds.
Substitution of the filter
Open the comfort panel.
Remove the metal grease filters.
Remove the charcoal filter as indicated in the picture.
Place the filter again into its seat.
Place again the metal grease filters into their place.
Lighting
LIGHT REPLACEMENT
20 W halogen light.
• Remove the snap-on lamp cover by levering it from under the
metal ring, supporting it with one hand.
• Remove the halogen lamp from the lamp holder by pulling
gently.
• Replace the lamp with a new one of the same type, making
sure that you insert the two pins properly into the housings on
the lamp holder.
Replace the snap-on lamp cover.