Charcoal filter (ductless version)
This filter cannot be washed or regenerated. It must be replaced when the EF appears on the
display or at least once every 4 months.
Activation of the alarm signal
In the recycling version hoods the filter saturation alarm must be activated during the instal-
lation or later.
Switch off the hood and the lights.
Disconnect the hood from the main voltage supply.
After restoring the connection press and hold B-key.
When releasing the key two rotating rectangles appear on the display.
Within 3 seconds press the B-key until a flashing confirmation appears on the dispaly:
2 flashes with EF - charcoal filter saturation alarm ACTIVATED
1 flash with EF - charcoal filter saturation alarm DEACTIVATED.
REPLACING THE CHARCOAL FILTER
Reset of the alarm signal
• Switch off the hood and the lighting. If the 24h-function has
been activated this has to be deactivated.
Press the E-key until the display is unlit.
Replacing of the filter
Open the comfort panels pulling them downwards.
Remove the metal grease filters.
• Remove the saturated charcoal filter by releasing the fixing
hooks
Fit the new filter and fasten it in its correct position.
Put the metal grease filters in their seats.
Close the comfort panels.
Lighting
LIGHT REPLACEMENT
20 W halogen light.
• Remove the 2 screws fixing the Lighting support, and pull it
out of from the Hood.
Extract the lamp from the Support.
• Replace with another of the same type, making sure that the
two pins are properly inserted in the lamp holder socket holes.
• Replace the Support, fixing it in place with the two screws re-
moved as above.