Frigidaire 316901301 Range User Manual


 
32
WARNING
Fig. 1
Left-hand rail and release
Right-hand rail and release
Keep warm
drawer
& handle
Removing and replacing keep warm drawer
Electrical Shock Hazard can occur and
result in serious injury or death.
Disconnect appliance from electric
power before cleaning and servicing
the warm drawer.
To remove the keep warm drawer:
1. Turn power OFF before removing the drawer.
2. Open the keep warm drawer completely.
3. On left drawer rail, locate black release lever and press up
with finger while pulling out slightly on the drawer handle.
On right drawer rail, locate black release lever and press
down with finger while pulling out slightly on the drawer
handle (See Fig. 1).
4. The drawer should now be released from the rails.
Remove keep warm drawer (using level & square motion)
completely away from the appliance.
To replace the keep warm drawer:
1. Pull the bearing glides to the front of the outer
compartment glide channels until they snap into place
(refer to Fig. 3).
2. Carefully line up both sides of the keep warm drawer
glide rails to the outer compartment glide channels
located inside the empty drawer compartment (Refer to
Fig. 2).
3. While holding the drawer level and square using the
keep warm drawer handle, push (DO NOT FORCE) the
drawer all the way into the outer compartment glide
channels all the way into the range. Pull the drawer
open again to verify the glides have seated.
4. If you do not hear the levers “click” or the bearing
glides do not feel seated remove the keep warm
drawer and repeat steps "1" through "3". This will
minimize possible damage to the bearing glides.
You may remove the keep warm drawer should it be
necessary for cleaning. Follow the steps below when
removing or replacing the keep warm drawer.
Fig. 2
Fig. 3
NOTE
The keep warm drawer will not operate whenever
operating a self-cleaning cycle.
Left & right compartment glide channels
CARE & CLEANING