Specifications
subject to change.
FRIGIDAIRE®
USA
•
250 Bobby Jones Expressway
•
Martinez, GA 30907
•
1-800-FRIGIDAIRE
•
frigidaire.com
CANADA
•
5855 Terry Fox Way
•
Mississauga, ON L5V 3E4
•
1-800-265-8352
•
frigidaire.ca
FGMV174K 05/09 © 2009 Electrolux Home Products, Inc. Printed in the U.S.A.
Microwaves
FGMV174K F/ M Over-The-Range
Ducted Option Specifications
•
For outside ventilation.
•
Exhaust duct adapter will be needed for outside ventilation, to mate
with standard 3-1/4" x 10" rectangular duct. If round duct required,
rectangular-to-round transition adapter will be needed with no less
than 6" diameter.
•
For most efficient airflow exhaust, use a straight run or as few elbows
as possible with a maximum duct length of 3-1/4" x 10" rectangular or
6" diameter round duct, not to exceed 140 equivalent feet.
•
For horizontal installation, be sure to allow enough space between
wall studs to accommodate exhaust.
•
Refer to installation instructions on web for detailed duct
preparation and converting exhaust vent blower system for exterior
exhaust ventilation.
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
•
36" Stainless Steel Filler Panel Kit – (PN # MWFILKTSS).
Microwave Specifications
•
Product Shipping Weight (approx.) – 60 Lbs.
•
Voltage Rating – 120V / 60 Hz / 15 Amps
•
Connected Load (kW Rating) @ 120 Volts = 1.64 kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
•
Amps @ 120 Volts = 14.2 Amps
•
Always consult local and national electric codes.
•
Grounded outlet should be located in cabinet above, with hole in base
to route power cord. Carefully follow top template instructions for
power cord clearance when installing beneath smooth, flat cabinets.
•
Microwave’s exhaust ventilation system is preset to recirculate air
inside with no ducting system required. Exhausting air outside is
optional, using either vertical or horizontal ducting system. (Refer to
Ducted Option Specifications for outside ventilation.)
•
For safe and proper installation, microwave MUST be mounted to
BOTH a top cabinet AND a wall, and connected to at least one wall
stud. Can NOT be installed in island or peninsula cabinet arrangements.
•
Cabinet bottom MUST be level to insure proper installation.
•
Cabinet MUST be capable of supporting a total load of 110 lbs.
•
Filler blocks recommended for installation when cabinet front hangs
below recessed bottom shelf.
•
Minimum distance of 30" required from cooking surface to bottom
edge of top cabinet.
•
Minimum distance of 66" required from floor to top of microwave.
•
Opening between cabinets MUST be 30" wide and free of obstructions.
For openings up to 36" wide, order optional 36" Filler Panel Kit to fill
in gap between unit and cabinets.
•
Allow 26" minimum clearance for 90° door swing.
30" Over-the-Range Microwave w/ Side Controls
Gallery (1.7 Cu. Ft.)