GAS COOKTOP INSTALLATION INSTRUCTIONS
8
Refer to the Use and Care Guide packaged with
the cooktop for operating instructions and for care
and cleaning of your cooktop.
Operation of electric igniters should be
checked after cooktop and supply line
connectors have been carefully checked for
leaks and the cooktop has been connected to
electric power.
:
A. Push in and turn a surface burner knob
to the LITE position. You will hear a small
ticking noise; this is the sound of the
electric ignitor which lights the burner.
B. After the burner lights, turn to the desired
ame size. The controls do not have to be
set at a particular mark. Use the marks as
a guide and adjust the ame as needed.
120 volt, 60 Hertz, properly grounded branch
circuit protected by a 15 amp circuit breaker or
time delay fuse. Do not use an extension cord
IMPORTANT Please read carefully.
The power cord of this appliance is equipped with
a 3-prong (grounding) plug which mates with a
standard 3-prong grounding wall receptacle (see
Figure 9) to minimize the possibility of electric
shock hazard from the appliance.
The wall receptacle and circuit should be checked
by a qualied electrician to make sure the
receptacle is properly grounded.
Where a standard 2-prong wall receptacle is
installed, it is the personal responsibility and
obligation of the consumer to have it replaced by
a properly grounded 3-prong wall receptacle.
Preferred Method
Grounding type
wall receptacle
Do not, under any
circumstances,
Power supply
cord with 3-prong
grounding plug.
Do not, under any circumstances, cut or
WARNING
Disconnect electrical supply cord
from wall receptacle before servicing cooktop.