Frigidaire LFEV36FE Ventilation Hood User Manual


 
7
CONNECT WIRING
WARNING: To reduce the risk of electric shock,
make sure power is switched off at the service
panel. Lock or tag service panel to prevent power
from being switched on accidentally.
HOUSE
WIRING
(120 VAC)
CARDBOARD
(Use to protect
cooktop)
1 Connect House Wiring (120 VAC) to hood. Use a piece of
Cardboard to protect the cooktop, if necessary.
2 Connect house black to hood black wire, house white to hood
white wire, and house ground under
Green Ground Screw.
Securely tighten cable clamp onto house wiring.
GREEN
GROUND
SCREW
INSTALL HOOD
KEYHOLE (4)
MOUNTING SCREW (4)
1 Hang hood from (4) Mounting Screws. Slide hood towards
wall until mounting screws are engaged in narrow end of (4)
Keyholes. Tighten mounting screws securely. A long
screwdriver works best.
5 Replace filters, turn on power at service panel, and test for
proper operation.
3 Connect ductwork to hood. Use Duct Tape to make joints
secure and air tight.
DUCT
TAPE
2 Replace bottom cover.
PAR20,
50W MAX.
HALOGEN
BULB (2)
- or -
R16,
40W MAX.
INCANDESCENT
BULB (2)
4 Install (2) PAR20, 50 W Maximum Halogen Bulbs or (2) R16,
40 W Maximum
Incandescent Bulbs. Purchase bulbs
separately.
!
CAUTION: Bulbs may be hot! Refer to bulb packag-
ing for further information.