Frigidaire PL42WC51EC Ventilation Hood User Manual


 
- 8 -
INSTALL FILTERS
(DUCTED AND NON-DUCTED HOODS)
1. To remove the GREASE filter, push in on the metal latch tab and tilt filter
downward to remove.
2. To install the GREASE filter, align rear filter tabs with slots in the hood. Depress
the metal latch tab, push filter into position and release. Make sure filter is
securely engaged after installation.
NOTE: Prior to use, remove protective film from the filter frame.
(NON-DUCTED HOODS ONLY)
1. To remove the NON-DUCTED RECIRCULATION filters, rotate them.
2. To install the NON-DUCTED RECIRCULATION filters, position the filter over
the blower; rotate to lock filters in place (Fig. 16).
3. Install GREASE filters after Non-ducted Recirculation filters are installed.
NON-DUCTED
RECIRCULATION
FILTERS
FIG.15
FIG.16
GREASE FILTERS
3.9x9.5mm
MOUNTING SCREWS
INSTALL THE HOOD, cont’d
8. Carefully place the decorative flue on the hood. Fig. 13.
- On ducted installation in rooms with 8-foot ceilings, the air vents are concealed. Install the flue with the air vents
down.
- On non-ducted installations in rooms with 8-foot ceilings, the air vents are exposed. Install the flue with the air vents
up.
- On ducted and non-ducted installations in rooms with 9-foot ceilings, the vents are exposed. Install the flue with air
vents up.
ROOMS WITH 10-FOOT CEILINGS
(DUCTED HOODS ONLY)
Rooms with 10-foot ceilings require flue extension model FXWC51EC available from your local dealer.
9. Discard the upper flue supplied with the product. Replace it with the flue extension.
10. Raise the upper flue until its holes align with holes in the flue mounting bracket (located on ceiling). Fig. 14.
12. Secure the flue with (2) 3.9x9.5mm mounting screws. Fig. 14.
FIG.14
LOWER
FLUE
FIG. 13
UPPER
FLUE
UPPER FLUE
VENTS EXPOSED
LOWER
FLUE
UPPER FLUE
VENTS
CONCEALED