5-3
5.3 Annual/Periodic System Inspection
This appliance should be inspected and adjusted periodically by qualified service personnel as
part of a regular kitchen maintenance program.
Frymaster recommends that this appliance be inspected at least annually by a Factory
Authorized Service Technician as follows:
Rethermalizer
• Inspect the cabinet inside and out, front and rear for excessive moisture
• Verify that the heating element wires are in good condition and that leads have no visible fraying
or insulation damage and that they are free of moisture.
• Verify that heating elements are in good condition. Inspect the elements for signs of extensive
dry-firing.
• Verify the heating-element amp-draw is within the allowed range as indicated on the appliance’s
rating plate.
• Verify that the temperature and high-limit probes are properly connected, tightened and
functioning properly, and that mounting hardware and probe guards are present and properly
installed.
• Verify that component box and contactor box components (i.e. computer/controller, relays,
interface boards, transformers, contactors, etc.) are in good condition and free from oil and other
debris.
• Verify that component box and contactor box wiring connections are tight and that wiring is in
good condition.
• Verify that all safety features (i.e. contactor shields, drain safety switches, reset switches, etc.)
are present and functioning properly.
• Verify that the vat is in good condition and free of leaks and that the frypot insulation is in
serviceable condition.
• Verify that all wiring harnesses and connections are tight and in good condition.