Frymaster 8196428 Fryer User Manual


 
1-12
10. Reconnect the unit to the electrical power supply, and verify that the pump is functioning
correctly (i.e., when a filter handle is placed in the ON position, the motor should start and there
should be strong suction at the intake fitting and outflow at the rear flush port.)
11. When proper operation has been verified, reinstall the back panels and the filter pan and lid.
12. Reposition the fryer under the exhaust hood and reconnect it to the electrical power supply to
return the fryer to service.
1.9.3 Replacing the Filter Transformer or Filter Relay
Disconnect the fryer from the electrical power supply. Remove the controller from the fryer to
expose the interior of the component box. The filter transformer and relay are located as shown in
the illustration on the next page. The components are held on by threaded pin studs so that only
removal of the nut is required to replace the component.