Frymaster CE Water Dispenser User Manual


 
9
Plug is in the bottom of the
filter pan or in the line from the
filter to the pump.
Disconnect the tubing from
the filter pan to the motor.
Make sure the pipe is cool.
The line is clear.
Reconnect hose to the
pump inlet.
Can you blow air
through it?
Yes
No
The line is clogged.
Run a cable through the
line to clear clogs.
Continue until you can
blow air through it.
Turn pump ON.
Does oil flow?
Conduct normal
filter operations.
Yes
No
There may be a plug in
the oil return line
system.
Disconnect the oil return line
running from the pump to the oil
return valve. Clean the pipe to
remove residual shortening.
Disconnect the oil return line
running from the oil return valve
to the frypot. Clean the pipe to
remove residual shortening.
Reconnect the oil
return lines.
Turn pump ON.
Does oil flow?
Conduct normal
filter operations.
Yes
No
Contact your
Factory
Authorized
Servicer.
Enter from
page 8 here.
DANGER!
NEVER USE A PROPANE TORCH
TO MELT SOLIDIFIED
SHORTHENING IN ANY PART OF
THE SYSTEM. YOU WOULD BE
USING AN OPEN FLAME NEAR
COMBUSTIBLES. THE FIRE
HAZARD IS EXTREME!