Frymaster Combinations Fryer User Manual


 
4-5
4.4 Disassembly, Cleaning, and Reassembly of the Magnum Leaf Filter
Flatbottom Series electric fryers with built-in filtration come equipped with a Magnasol Magnum
Leaf Filter, which eliminates the need for filter paper. Follow the instructions below to disassemble,
clean, and reassemble the filter.
Dissassembly
1. Unscrew the standpipe from the leaf filter assembly and set it aside.
Step 2 - Grasp frame with
thumbs on these handles and
pull frame appart at corner.
Step 1 - Unscrew
standpipe and set
aside.
Step 3 - Separate
the outer screens
and grid.
2. Grasp the frame with your thumbs on the handles at the corner of the assembly and pull outward
in opposite directions to separate the frame at the corner. Continue to open the frame (it will
pivot at the opposite corner) until the outer screens and grid can be removed from the frame.
3. Separate the outer screens and grid.
Cleaning
1. Clean the two frame pieces, outer screens, and grid using a good quality degreaser and hot water
from a spray nozzle. The groove in the frame pieces can be cleaned with the edge of a Scotch-
Brite™ or similar cleaning pad.
2. At each scheduled boil out, disassemble the leaf filter assembly and place in the frypot being
boiled out. Follow the boil-out procedure in Section 2.3.
3. Allow all leaf filter assembly components to air dry or thoroughly dry with clean towels before
reassembling.