Frymaster EH1721 SERIES Fryer User Manual


 
EH1721 SERIES ELECTRIC FRYERS
CHAPTER 4: BUILT-IN FILTRATION
4-8
4.3.2 Filter Operation (cont.)
5. After all oil has drained from the frypot into
the filter pan, pull the yellow handle to open
the oil return lines and activate the filter
pump.
6. Oil will begin to pump from the filter pan
into the frypot. Allow the oil to circulate for
approximately 5 minutes to remove
suspended particles. If the frypot sides and
bottom have sediment deposits, lift the
heating elements and clean the frypot with
the cleaning brush included with the fryer.
7. After the oil is filtered, close the drain valve
(push the red handle until it stops) and allow
the fryer to refill.
Pull the yellow handle to open the oil return valve
and activate the filter pump.
Allow the oil to circulate for 5 minutes to ensure all
sediment and suspended particles are removed.
Frypot refilling with filtered oil.