Frymaster HLZ Toaster User Manual


 
HEATED LANDING ZONE
CHAPTER 6: OPERATOR TROUBLESHOOTING
8
Symptom Possible Cause
No computer display; no flow from
air tower
No power
Circuit breaker out
Low voltage
Bad fuse
Bad transformer
Hi-limit out
No flow from air tower
Bad latching relay
After 20 minutes of operation
computer display shows PROB
RTD probe has failed. Isolate failed component
by checking temperature of air and heater plate
with the temperature display keys on the
computer. The plate temperature should be
within ± 15°F of setpoint. The air heat should be
within ± 25°F of setpoint. If both temperatures are
good, the computer is likely bad.
After 20 minutes of operation
computer display shows HI
Plate heater, plate heater relay or RTD are faulty.
After 20 minutes of operation
computer display shows LO
Air heater, air heater relay or RTD are faulty