Dean
™
®
Super Runner Value Gas Fryers
Model #_______________
CSI Section 11400
5489 Campus Drive
Shreveport, LA 71129
USA
Tel: 318-865-1711
Tel: 1-800-221-4583
Fax: 318-868-5987
E-mail: info@dean.enodis.com
http://dean.enodis.com
Bulletin No. 830-0117 10/08
Litho in U.S.A. ©Frymaster, LLC
MODEL MIN./MAX.
OIL
CAPACITY
OVERALL SIZE mm DRAIN
VALVE
mm
DRAIN
VALVE
HEIGHT
mm
NO.
OF
TUBES
FRYING
AREA mm
APPROXIMATE SHIPPING DIMENSIONS
OVERALL
HEIGHT
WORK
HEIGHT
WIDTH
A
LENGTH CLASS SHIPPING
lbs./cu.ft.
(kg/m
3
DIMENSIONS
mm
SR42G 35-43 lbs.
(17-32 liter)
45”
(1143)
35”
(890)
15-1/2”
(394)
29-1/4”
(743)
1”
(25)
18-3/8”
(467)
3 14” x 14”
(356 x 356)
85 150 lbs./15
(68/0,42)
48-1/2”
(1232)
20-1/2”
(521)
36”
(914)
SR52G 35-50 lbs.
(17-25 liter)
45”
(1143)
35”
(890)
15-1/2”
(394)
29-1/4”
(743)
1-1/4”
(32)
17-1/2”
(445)
4 14” x 14”
(356 x 356)
85 180 lbs./15
(82/0.42)
48-1/2”
(1232)
20-1/2”
(521)
36”
(914)
SR62G 60-75 lbs.
(34-42 liter)
45”
(1143)
35”
(890)
20”
(508)
35-1/2”
(902)
1-1/4”
(32)
19-3/4”
(501)
5 18 x 18”
(457 x 457)
85 255 lbs./28
(116/0,79)
H
48-1/2”
(1232)
W
20-1/2”
(521)
L
36”
(914)
DIMENSIONS
POWER REQUIREMENTS
SHORT TERM SPECIFICATION
The following description will assist with ordering the features
desired for this equipment:
Shall be DEAN free-standing cool zone deep fat fryer, Model
_________. Only ________ wide, _________# oil capacity, requir-
ing ____________Btu/hr. natural or LP gas input (3/4” N.P.T.
connection) and mechanical controls.
ORDERING DATA
Please specify:
Natural or propane gas
Altitude -- if above 2000 ft. (610 m)
NOTE:
DO NOT CURB MOUNT.
*Do not exceed 14” W.C. or 1/2 PSI.
TOP VIEW
FRONT VIEW
(51)
2.00
SIDE VIEW
7.20
(183)
35.00
(889)
7.62
(194)
47.00
(1194)
CONNECTION
w/ 3/4" NPT PIPE
(36)
1.4
GAS LINE
(mm)
INCHES
35.5
(902)
45.00
(1143)
DEAN
A
We reserve the right to change specifications appearing in this bulletin without incurring any obligation for equipment previously or subsequently sold.
MODEL NATURAL OR LP GAS
INPUT RATING
GAS
CONNECTION
ELECTRICAL
REQUIREMENT
SR42G 105,000 Btu/hr. (26,481 kcal) (30.8 kw) 3/4” N.P.T.
*Regulator not required
NONE
SR52G 120,000 Btu/hr. (30,600 kcal) (35 kw)
SR62G 150,000 Btu/hr. (37,783 kcal/hr.) (44 kw)