Fujioh FDR-4200 Ventilation Hood User Manual


 
5. FINAL ASSEMBLY AND CHECK
Two 60 W light bulbs (not supplied) can be mounted to this range hood. Prior to final
assembly, install light bulbs (in the base diameter 26 mm), rated 120 V - 60 W or
below.
1
Assembly (refer to “PREPARATION”)
(1) The oil tray is attached with tape on the
bottom inside of the body, so be sure to
remove the tape before operation.
(2) Replace the slot filters with 2 screws.
(3) Replace the Rectifier Baffle Panel with 2 screws.
(4) Replace the oil receiving cover.
2
Check
(1) Turn on the electrical circuit to the range hood.
(2) Make sure that the switch and light operate correctly.
Refer to page 5 of the Operation Manual.
(3) Check the ventilating functions at Hi, Me and Lo positions.
(4) Make sure that the range hood has no abnormal noises and/or vibration.
CAUTION: To reduce the risk of injury, keep your hands and other
objects away from the fan while it is in motion.
Wear working gloves to avoid injury.
12