Fujitsu MAN3367 Water Dispenser User Manual


 
C141-E124-01EN 5 - 17
Table 5.3 Sense data error classification (2 of 4)
K
*
C
*
Q
*
Outline of Error L
*
Recovery Method
(See Table 4.4.)
31 00 Medium form at corru
p
ted Need 18
FORMAT command failed
3
31 01
The data format on the disk media is not correct.
403xxPeri
p
heral device write fault Need 7
32 01 Defect list update failure
These are errors detected in the operation of the
disk drive.
4 15 xx Positionin
g
error Need 12
This is an error of the disk drive's seek system.
4 32 00 No defect s
p
are location available None 19
No usable alternate blocks exist on the disk drive.
4 40 nn Diagnostic failure on component 'nn' Need 13
An error was detected in the IDD's self-diagnosis.
4 44 nn Internal tar
g
et failure Need 20
An internal hardware error or a microcode
detection error was detected in the IDD.
4 4C xx Calibration failed Need 10
C4 xx Drive failure
The initial seek was terminated abnormally. Or, a
serious error was detected in the drive's control
system.
5 20 00 Invalid command o
p
eration code None 2
21 00 Logical block address out of range
24 00 Invalid field in CDB
25 00 Logical unit not supported
26 00 Invalid field in parameter list
There is an error in the command specification
contents.
5 3D 00 Invalid bits in IDENTIFY messa
g
eNone3
90 00 Initiator's SCSI ID not identified
An error was detected in the SCSI protocol in the
command execution sequence.
6 29 xx Power on, reset, or BUS DEVICE RESET occurred None 14
The IDD was initialized by a Power on, RESET
condition or BUS DEVICE RESET message.
* K: Sense Key C: Sense Code
Q: Sub-sense code L: Logging Necessary? (shown in Section 5.2.3)