Electrical connection
Rated power consumption: 4 400 W
Note:
if there is a need for an intermediate cupboard wall
under the hob, cut out the recess so that the trough
of the hob does not lie on the cupboard side wall
and so that a distance of 20 mm (
13
/
16
´ ´ ) from the
intermediate cupboard wall is guaranteed.
Please note that a distance of 10 mm (
13
/
32
´ ´ ) from the
base cabinet must be observed for safety reasons.
(see figure)
Only a qualified electrician should install this
appliance.
This appliance must be hardwired.
The mains connecting cable must at least
correspond to the type SJTO 3x16 AWG 105°C.
The mains connecting cable must only be
purchased through and connected by an
authorised specialist. The appliance must be
properly grounded. Pay attention to the
information on the rating plate.
16
Note:
when installing a shelf, observe a distance of at
least 20 mm (
13
/
16
´ ´ ) from the bottom edge of the
housing trough to the shelf or the next combustible
item of furnishing.