10. Install a 4” exhaust clamp onto the
Banks Monster Muffler inlet. Connect
the muffler inlet onto the rear of the
extension pipe. Install the 4” muffler
clamp onto the Monster muffler outlet
such that the hanger pins are towards
the front of the vehicle. Install the
hanger pins into the vehicle’s rubber
insulators.
11. Route the tailpipe over the rear
axle housing and into the muffler
outlet. Install the tailpipe hanger pin
into the corresponding rubber hanger.
Loosely snug the 4” clamp onto the
muffler outlet.
12. For Models with storage boxes: Adjust
the tailpipe turndown parallel with the
ground so that the bumper or storage
boxes do not get in the path of the
exhaust (see Figure 3).
13. For Models without storage boxes:
Install the 5” Monster tailpipe tip on
the exhaust. Keep the wrapping on
until installation is complete. The tip
should be rotated so the clamp nut
and drain hole are pointing down.
Align the end of the tip with the
body line of the truck. Remove the
protective covering from the tailpipe
tip.
Caution: The protective covering may ignite
and burn if not removed prior to running the
engine.
14. With everything positioned
properly, begin to tighten the clamps
starting with the ones closest to the
front and working your way back.
Torque the exhaust clamps evenly to
35 ft-lbs. Make sure that each slip is
fully inserted (+/-
1
4 inch) and that
all mount hangers are in the forward
position (see Figure 4). Torque V-band
clamp on the T.O.P. to 7 ft-lb.
15. Your system includes two “Banks
Power” logos designed to complement
the Ford badging on your truck. Use
Figure 3