Garland 36 E Range User Manual


 
Garland Commercial
Industries, LLC
185 East South Street
Freeland, PA 18224
Phone: (570) 636-1000
Fax: (570) 636-3903
Garland Commercial Ranges Ltd
1177 Kamato Road,
Mississauga, Ontario
L4W 1X4 CANADA
Phone: 905-624-0260
Fax: 905-624-5669
Enodis UK LTD
Swallowfield Way,
Hayes, Middlesex
UB3 1DQ ENGLAND
Telephone: 081-561-0433
Fax: 081-848-0041
36 E Series Heavy Duty Combination Top Range
Form# 36ER32-3 (07/07)
36"
[914mm]
24"
[610mm]
6"
[152mm]
36"
[914mm]
30"
[762mm]
18"
[457mm]
15"
[381mm]
24"
[610mm]
36"
[914mm]
REAR
ELECTRICAL
INLET
6"
[152mm]
6"
[152mm]
6"
[152mm]
33-3/4"
[857mm]
14-1/2"
[368mm]
18"
[457mm]
63"
[1600mm]
With "DD"
Hi Shelf
31-3/8"
[797mm]
With STD.
Backguard
NOTE: Add 2" [51mm]
to depth for RC Models
Modular Top
12" [305mm]
MODEL
TOTAL
kW
3-PHASE
kW PER PHASE
ALL VOLTAGES
NOMINAL AMPERES PER LINE
SINGLE
PHASE
THREE PHASE
208V 240V
X-Y Y-Z X-Z 208V 240V X Y Z X Y Z
36ER32-3 20.7 6.5 4.2 10 99 88 69 45 60 61 40 53
36ES/ET32-3 14.2 5 4.2 5 68 60 42 39 39 37 34 34
36ERC32-3 19.6 5 4.6 10 94.2 81.7 44 40 61 38 35 53
CLEARANCES
ENTRY
TO COMBUSTIBLE
WALL
CRATED UNCRATED SIDES REAR
41-1/4"
(1048mm)
36-1/4"
(921mm)
3"
(76mm)
1-1/2"
(38mm)
NOTE:  For ranges with convection oven(s), (models
with sux ‘RC’), air circulation is required for proper
operation of fan motors. These models must not be
dais mounted or installed with out legs.
Shipping Cubic Feet 51; Modular 20
Garland products are not approved or authorized for
home or residential use, but are intended for commer-
cial applications only. Garland will not provide service,
warranty, maintenance or support of any kind other
than in commercial applications.