Garland GIU 3.5 (SH/BA 3500) Cooktop User Manual


 
Part # 4521635 (03/04/08) Page 13
Number Of
Flashing Signals
Error Code
Signicance
(Asterisk Refers To Notes At End
Of Chart)
Measures To Take
8
-........-........-........
Sensor error*** a. Check Cu coil
b. Check heat sink sensor
c. Check RTCS-sensor
d. Check board sensor
12 Power reduction, heat sink
temperature **
a. Turn the power level down
b. Check fan
13 Power reduction, temperature of
cooking surface **
CU sensor 1
Warning temperature
a. Take pan o until cooking area has cooled down
b. Wait until it has cooled down
c. Check coil
17 CU sensor 1 over
temperature ***
a. Temperature of the cooking eld too high
b. Check CU sensor 1, index value 5 -Ohms at 25°C (77°F)
18 CU sensor 2 over
temperature ***
a. Temperature of the cooking eld too high
b. Check CU sensor 2, index value 5 -Ohms at 25°C (77°F)
19 CU sensor 2, high temperature
warning
a. Temperature of the cooking eld too high
b. Turn the power down
20 Power reduction generator inside
temperature **
a. Check for heat sources around the generator and remove
them if any
b. Check air circulation
21 Heat sink sensor error *** a. Contact the factory
24 Board temp. sensor error *** a. Exchange power unit
25 CU sensor 1 error *** a. Check CU sensor 1 for short circuit or discontinuation, index
value 5 Ohms at 25°C (77°F).
26 CU Sensor 2 error *** a Check CU sensor 2 for short circuit or discontinuation, index
value 5 Ohms at 25°C (77°F)
27 Empty cooking detector CU
sensor 1 *
a. Check cooking material in the pan
28 Empty cooking detector CU
sensor 2 **
a. Check cooking material in the pan
* The induction unit can only be restarted by turning the control knob rst to the “OFF” position, and then back to
the “ON” position to reset.
** The induction unit continues working
*** The induction unit does not heat.