Garland S18-FS Fryer User Manual


 
Part # P156 Rev 1 (12/03/09) Page 11
F=4.0kW F=4.0kW F=4.0kW
THERMOSTAT
200°-375°F
1
6
3
5
2
4
454443424140
4
2
5
3
6
1
20
20
23
23
22
30
19
1817
16
15
14
16
18
14
24
10
25
29
40
44
42
10
27
22
43
41
12
12
24
25
28
21
30
2926
26
11
21
17
19
15
11
28
13
13
45
1
6 35 2
4
4kW/4.5kW
4kW/7.0kW
4kW/4.5kW
3013800
TH1
TH2
S1-1
S1-2
K
K2
RED
GREEN
AMBER
K
K2
S
TH1
TH2
:
MODEL
GARLAND COMMERCIAL RANGES LIMITED
MISSISSAUGA, ONTARIO, CANADA
S18F, SF (208/240 VAC)
DWG
:
SWITCH
TOP
G
X
3 PHASE
Y
Z
30A
30A
1 PHASE
G
Z
X
Y
LIMIT CONTACTOR
REGULATING
CONTACTOR
SF=4.5kW SF=7.0kW SF=4.5kW
SF=40A
F=30A
COM NO NC
HIGH LIMIT
GREEN, POWER ON
AMBER, HEATING
RED, t>LIMIT
CIRCUIT 2
CIRCUIT 1
X
Y
Z
SCHEMATIC DIAGRAM