Garland SGM-100S1 Convection Oven User Manual


 
Garland Commercial
Industries, LLC
185 East South Street
Freeland, PA 18224
Phone: (570) 636-1000
Fax: (570) 636-3903
Garland Commercial Ranges Ltd
1177 Kamato Road,
Mississauga, Ontario
L4W 1X4 CANADA
Phone: 905-624-0260
Fax: 905-624-5669
Enodis UK LTD
Swallowfield Way,
Hayes, Middlesex
UB3 1DQ ENGLAND
Telephone: 081-561-0433
Fax: 081-848-0041
“D”
TOP VIEW
38"
[965mm]
25-3/8"
[645mm]
54-9/16"
[1386mm]
3/4" N.P.T.
GAS INLET
3/4" REAR
GAS INLET
1" REAR
GAS INLET
7-3/4"
[197mm]
2"
[51mm]
3/4"
[19mm]
(includes
motor)
FLUE: 2-3/8" x 5"
[60mm x 127mm]
38-1/4"
[972mm]
11-1/2"
[292mm]
17-3/4"
[451mm]
1-1/4"
[32mm]
32-1/8"
[816mm]
34"
[864mm]
SINGLE DECK
FRONT VIEW
6-1/4"
[159mm]
DOUBLE DECK
FRONT VIEW
32-1/8"
[816mm]
32-1/8"
[816mm]
1-1/4"
[32mm]
32-1/8"
[816mm]
32-1/8"
[816mm]
14-3/4"
[375mm]
35-7/16"
[900mm]
Form# SGM (06/07)
Summit Gas Convection Oven
Gas Input Ratings shown here are for installations up to
2,000 ft. (610m) above sea level. Specify altitudes over
2,000 ft.
Notes:
1. Standard electrical specifications include motor requirements.
2. (120V units) 115V, 3/4 HP, 2‑speed motor; 1140 and 1725 rpm, 60Hz.
3. (240V units) 200‑240V, 3/4 HP, 2‑speed motor; 1140 and 1725 rpm, 60 Hz
4. A 6 ft. line cord is provided for each 120V deck with a
(NEMA #5‑15P) plug.
5. U. S. Range recommends a separate 15 AMP circuit for each 120V unit.
Model
Int. Dimensions :In (mm) Ext. Dimensions: In (mm) Ship Wt Ship Dim.
W H D W H ** D (w/motor) Lbs/kg Cubic Ft.
SGM‑100S1 29 (736) 24 (610) 24 (610) 38 (965) 57‑1/2 (1461) 41‑1/4 (1048) 510/232 42
SGM‑100D1 29 (736) 24 (610) 28 (711) 38 (965) 57‑1/2 (1461) 44‑1/2 (1130) 510/232 42
SGM‑200S1 29(736) 24(610) 24(610) 38(965) 70‑1/2 (1791) 41‑1/4 (1048) 1024/464 84
SGM‑200D1 29(736) 24(610) 28 (711) 38(965) 70‑1/2 (1791) 44‑1/2 (1130) 1024/464 84
** Height with or without standard casters. Height with low prole casters (double deck) is 68‑1/2" (1740mm).
Models
Input Ratings, Natural & Propane Operating Pressure * Electrical Specications
BTU/hr kW Equiv. Gas Inlet Natural Propane 120V/1Ph. 240V/1Ph.
Single Deck 60,000 17. 6 (1 )@ 3/4" NPT
4.5" WC
(11 mbar)
10" WC
(25 mbar)
(1)@9.4A (1)@ 5.2A
Double Deck 120,000 35.2 (1 )@1" NPT
(2)@9.4A (2)@ 5.2A
*Maximum Pressure 13.8" WC @ 70°F (21°C)
Many local codes exist and it is the responsibility of the owner and installer to comply with those codes.
These appliances are intended for commercial use by professionally trained personnel.
Instillation Notes:
Combustible & Non-Combustible
Wall Clearances:
Sides 1" (25mm) Back 3" (76mm)
Entry Clearances: In (mm)
Crated 44‑1/2 (1130) Uncrated 32‑1/2 (826)