GE 200D8074P036 Refrigerator User Manual


 
31
Manufactured for: General Electric Company, Louisville, KY 40225
Performance Data Sheet
SmartWater Filtration System
M
SWF Cartridge
T
his system has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below. The concentration
of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible
limit for water leaving the system, as specified in NSF/ANSI 42/53.*
(100% safety factors built in for unmetered usage)
Standard No. 42: Aesthetic Effects
Parameter USEPA Influent Effluent %Reduction Min. Required
MCL ChallengeConcentration Average Maximum Average Minimum Reduction
C
hlorine 2.0mg/L+
1
0% 0.06 mg/L 0.10 mg/L 97% 95.1% ≥50%
Particulate** atleast 10,000 particles/mL 408,333 670,000 95.5% 89.4% ≥85%
Standard No. 53: HealthEffects
M
ax.Permissible
ProductWater
USEPA Influent Effluent % Reduction Concentration
Parameter MCL ChallengeConcentration Average Maximum Average Minimum mg/L
Turbidity 1 NTU*** 11 +1NTU*** 0.38 NTU 0.5NTU 96.5% 95.4% 0.5NTU
Cysts 99.95% Reduction Minimum50,000L < 1#/L 4 #/L >99.99% >99.99% 99.95%
Lead atpH 6.5 0.010mg/L 0.15 mg/L +10% <1 ppb < 1ppb 99.3% 99.3% 0.010 mg/L
Lead atpH 8.5 0.010mg/L 0.15 mg/L +10% 3.1ppb 9.0 ppb 98.0% 95.5% 0.010 mg/L
MercuryatpH6.5 0.002mg/L 0.006 mg/L+ 10% 0.34 ppb 0.7 ppb 94.1% 89.6% 0.002mg/L
MercuryatpH8.5 0.002mg/L 0.006 mg/L+ 10% 0.66 ppb 1.5 ppb 88.4% 73.7% 0.002mg/L
Lindane 0.0002mg/L 0.002 mg/L+ 10% <0.02ppb <0.02ppb >99.0% > 99.0% 0.0002mg/L
Atrazine 0.003mg/L 0.009mg/L +10% <0.5 ppb <0.5 ppb >93.9% >94.3% 0.003 mg/L
2,4-D 0.070 mg/L 0.210 mg/L+10% 7.7ppb 35 ppb 96.0% 82.0% 0.070mg/L
Toxaphene 0.003mg/L 0.015 mg/L +10% < 1ppb < 1ppb >92.9% > 92.9% 0.003mg/L
Benzene 0.005 mg/L 0.015mg/L +10% < 0.5 ppb < 0.5 ppb > 96.8% >97.0% 0.005mg/L
Carbofuran 0.040 mg/L 0.080 mg/L+ 10% <1 ppb < 1ppb > 98.7% >98.7% 0.04mg/L
P- Dichlorobenzene
0.075 mg/L 0.225 mg/L+ 10% < 0.5 ppb < 0.5ppb >99.7% > 99.8% 0.075mg/L
Asbestos 99% Reduction 10
7
to10
8
fibers/L;fibers>10µminlength <0.17MF/L <0.17 MF/L >99% >99% 99%
* Tested using pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 2.5°C)
** Measurement in Particles/ml. Particles used were 0.5-1 microns
*** NTU=Nephelometric Turbidity Units
Operating Specifications
Capacity: certified for up to 300 gallons (1135 l); up to six months for models without a replacement filter indicator light;
up to one year for models with a replacement filter indicator light
Pressure requirement: 20–120 psi (1.4–8.2 bar), non-shock
Temperature: 33–100ºF (0.6–38ºC)
Flow rate: 0.89 gpm (3.4 lpm)
General Installation/Operation/Maintenance Requirements
Flush new cartridge at full flow for 5 minutes to purge out trapped air.
Replace cartridge when flow becomes too slow.
Special Notices
Installation instructions, parts and service availability, and standard warranty are included with the product when shipped.
This drinking water system must be maintained according to manufacturer’s instructions, including replacement of filter cartridges.
Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts.
The contaminants or other substances removed or reduced by this water treatment system are not necessarily in your water.
Check for compliance with the state and local laws and regulations.
Note that while the testing was performed under standard laboratory conditions, actual performance may vary. Systems must be
installed and operated in accordance with manufacturer’s recommended procedures and guidelines.
NSF
®
System Tested and Certified by NSF International against NSF/ANSI Standard 42 & 53 for the reduction of:
Standard No. 42: Aesthetic Effects
Chemical Unit
Taste and Odor Reduction
Chlorine Reduction
Mechanical Filtration Unit
Nominal Particulate Reduction, Class I
Standard No. 53: Health Effects
Chemical Unit
Lead,Mercury andAtrazineReduction
Lindane, Toxaphene and 2,4-D Reduction
Benzene, Carbofuran and
P-Dichlorobenzene Reduction
Mechanical Filtration Unit
Turbidity Reduction, Cyst Reduction,
Asbestos Reduction