GE JGSS05GER Range User Manual


 
CONVERTING SURFACE BURNERS ON
MODELS EQUIPPED WITH SEALED BURNERS (See
Step 4 if range is equipped with dual burners.)
Burnercap~
1. Remove grates, burner caps and burner heads.
2. Remove burner bases by unscrewing the 3
small screws in each base.
~
burner
straight out.
DO
N~
disconnect the wires from the burner
bases unless the
cooktop
needs to be raised.
3. Remove the brass orifice spud under each
burner base by unscrewing spud from fitting with
a
7mm
or 5/16” wrench (depending on the size of
your spuds). Apply a 3/4” wrench to the hex
on
tie
gas inlet tube as a back-up when
removing spud to prevent
the
aluminum
tube
horn
twisting.
4. Install
or~lce
spuds
accordin
to one of the
d
following diagrams (see or B ), for
LP
gas or natural gas, depending on which you are
converting to.
orifice
Spuds
for
Conve~ingto
LpGas:
LP
orifice spuds are in a small plastic bag packed
with this Use and Care book.
LP
orifice spuds
have a 2-digit number and the Letter “L” on
one side. Each
ofilce
spud will also have 1 or 2
grooves on one side, denoting the location on
the range where it is to be installed.
mm
OfificeSpudsbrConvefiing
*o
Natural
Gas:
Natural gas orifice spuds have a 3-digit number
on one side. Each orifice spud will also have 1, 2
or 3 grooves on one side, denoting the location
on the range where it is to be installed.
Front of Range
(continued next page
41