GE JN327 Ventilation Hood User Manual


 
12
D.
Recirculating (non-vented ductless–
JN327 and RN328, and optional on JV347,
JV348 and JV367 models only)
Use the hood as a template and mark the locations
on the cabinet for the electrical wiring and keyhole
screw slots.
Since the hood is to be recirculated (not to be vented
outside), do not cut out any vent openings in the wall
or cabinet bottom.
Installation Instructions
Wood shims
(recessed-bottom cabinets only–shims must be a
minimum of 3/8thick and cut to fit the width
of the inner recessed cabinet bottom)
Cabinet front
Center line
Electrical access hole
(in wall)
Hood mounting screws (4)
Cabinet
bottom
13
3
4(30hood)
16
3
4(36hood)
1
1
4
1
2
3
3
4
5
1
4
5
1
4
7
3
4
13
3
4(30hood)
16
3
4(36hood)
C.
Outside rear exhaust
(Horizontal duct–3
1
4
x 10
Rectangular)
Use the diagram or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.
RUN WIRES
Run the electrical wires through the wall or
cabinet according to National Electrical Code
and applicable local codes.
NOTE: DO NOT turn the power on until installation
is complete.
13
CUT HOLES
Cut holes at marked locations for duct and electrical
wiring. For the vertical duct, cut out 3/4extra toward
the front of the cabinet so you can move the duct
freely when installing the hood. It may also ease
installation by cutting the hole 10
1
2instead of 10.
12
MARK HOLES
Select the vent option that your installation will require
and proceed to that section:
Hood mounting screws (4)
13
3
4(30hood)
16
3
4(36hood)
13
3
4
(30
hood)
16
3
4
(36
hood)
Cabinet front
Center
line
Electrical access hole
(in cabinet bottom)
Wood shims
(recessed-bottom
cabinets only–shims
must be a minimum of
3/8thick and cut to fit
the width of the inner
recessed cabinet bottom)
9
5
8
1
3
8
1
1
4
7
3
4
3
3
4
1
2
A.
Outside top exhaust
(Vertical duct–3
1
4
x 10
Rectangular)
Use the diagram or the hood as a template and mark
the locations on the cabinet for ductwork, electrical
wiring and keyhole screw slots.
B. Outside
top exhaust (Vertical duct–7 Round)
Use the diagram or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.
Hood mounting screws (4)
13
3
4(30hood)
16
3
4(36hood)
13
3
4
(30
hood)
16
3
4
(36
hood
)
Cabinet front
Center
line
Electrical access
hole
(in cabinet bottom)
Wood shims (recessed-bottom
cabinets only–shims must be a
minimum of 3/8thick and cut
to fit the width of the inner
recessed cabinet bottom)
Access
hole for 7
round duct
9
5
8
1
3
8
1
1
4
7
3
4
5
3
4
Cabinet
bottom
11
5
1
4
5
1
4
Cabinet Bottom
Vertical duct
access hole
8DIA.
HOLE
Horizontal duct
access hole