GE JN327, JV327, JV337, JV347 Ventilation Hood User Manual


 
3. POWER SUPPLY
A. CIRCUIT VOLTAGE: This hood must be connected
to a supply circuit of the proper voltage and frequency
as specified on the rating plate. Wire size must conform
to the requirements of the National Electrical Code or
the prevailing local code for hoods of this rating. The
rating plate is located on the rear wall of the hood.
B. FUSE RATING: 15 amps.
C. Unless otherwise specified by local codes, bring
a 15 amp 2 wire circuit with ground to the area of
the power supply connection box.
D. USE OF OPTIONAL TOP POWER SUPPLY:
The power supply can be attached through the top
knockout if desired, but only the top or back knockout
shall be opened (See Figs. 8, 9 and 10).
4. HOOD INSTALLATION
A. MECHANICAL
NOTE: When possible, it is more convenient to mount
and wire the hood before the base cabinet is put in place.
1. Take out 1 screw and remove the power supply
connection box cover located on the underside
of the hood (See Fig. 13 Model: JV327) (See Fig. 12
Models: JN327, JV337 & JV347).
2. To locate the 4 mounting holes, position the hood
carefully against the bottom of the wall cabinet and
mark the screw positions through the keyhole slots
in the hood. Drill 3/32 pilot holes for the mounting
screws in the small end of the keyhole.
3. Partially drive the 4 mounting screws so that the
heads of the screws extend 1/2below the bottom of
the cabinet. Raise the hood against the bottom of the
cabinet, making sure that the heads of the mounting
screws protrude through the hole section of the
keyhole slots as shown in Fig. 11. Before tightening
the mounting screws, attach the power supply cable
to the hood. Then push the hood back against the
wall and tighten the mounting screws.
7
Exhaust outlet connects to 3
1
4x 10rectangular duct; outlet has TOTAL
ADJUSTMENT of 1
1
2from side to side to simplify duct alignment.
NOTE: Exhaust outlet can
be installed as either TOP
or REAR by removing
desired knockout. Insert a
screwdriver under edge of
knockout. Break tabs and
remove knockout with pliers.
Power supply
entrance openings
in top and rear of hood.
NOTE: Use of REAR opening
is recommended.
1
1
4
1
1
4
1
1
4
1
1
4
1
1
4
FIGURE 10
FIGURE 8
FIGURE 9
FIGURE 11
Direction of
movement for mounting
Screws
Keyhole
slots
Centerline of hood
Power
supply entrance
openings in top
and rear of hood.
NOTE: Use of REAR opening
is recommended.
Power supply
entrance openings
in top and rear of hood.
NOTE: Use of REAR
opening is recommended.
Exhaust outlet connects to 7dia. duct.
Centerline of hood
Top exhaust
outlet only
7
3
4
7
3
4
7
3
4
1
1/2
3/4
Center line
Center
line