Optional Accessories (Available at additional cost)
HOOD EXHAUST DUCT
Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION: The hood exhaust has been designed to mate with a standard 3-1/4" x 10"
rectangular duct.If a round duct is required, a rectangular-to-round transition adaptor must be used. Do not
use less than a 6" diameter duct
REAR EXHAUST: If a rear or horizontal exhaust is to be used, care should be taken to align exhaust with
space between studs, or wall should be prepared at the time it is constructed by leaving enough space
between the wall studs to accommodate exhaust.
MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of 3-1/4" x 10"
rectangular or 6" diameter round duct should not exceed 140 equivalent feet.
ELBOWS, TRANSITIONS,WALL AND ROOF CAPS, etc., present additional resistance to airflow and are
equivalent to a section of straight duct which is longer than their actual physical size. When calculating the
total duct length, add the equivalent length of all transitions and adaptors plus the lengths of all straight
duct sections. The chart below shows the approximate feet of equivalent length of some typical ducts.
12" Filler Panel Kits
JX41–Black
JX40WH–White
15" Filler Panel Kits
JX48BL–Black
JX48WH–White
When replacing a 36" or
42" range hood, this kit fills
in the additional width to
provide a custom built-in
appearance. For installation
between cabinets only; not
for end-of-cabinet installation.
Each kit contains two 3"-wide
filler panels.
Filter Kits
JX81DRecirculating
Charcoal Filter Kit
(included with
non-vented models)
To be used when the
Spacemaker microwave
oven cannot be vented
to the outside.
Specification Created 10/03
340111
Duct Equivalent Feet
A. Rectangular-To-round 5 ft.
Transition Adaptor
B. Wall Cap 40 ft.
C. 90° Elbow 10 ft.
D. 45° Elbow 5 ft.
E. 90° Elbow 25 ft.
F. 45° Elbow 5 ft.
G. Roof Cap 24 ft.