GE Over the Range Instructions Microwave Oven Microwave Oven User Manual


 
AFTER: Fan Blade
Openings Facing
Forward
5
4
3
6
ADAPTING MICROWAVE
BLOWER FOR RECIRCULATION
C4.
20
NOTE: The exhaust adaptor with damper is not
needed for recirculating models. You may want to
save them for possible future use.
Carefully pull out the blower unit. The wires
will extend far enough to allow you to adjust the
blower unit.
Roll the blower unit 90° so that fan blade openings
are facing toward the front of the microwave.
Roll
Slide exhaust adaptor to one side and remove it.
Remove and save the screw that holds the blower
motor to the microwave.
Blower Plate
Blower Motor
Screw
Back of
Microwave
Remove
and save
screw that
holds blower
plate to
microwave.
Lift off the
blower plate
and attached
adaptor from
the microwave.
NOTE: Make sure wires remain routed in the
grooves of the motor frame.
Installation Instructions
BEFORE: Fan Blade
Openings Facing Up
Damper
Back of
Microwave
CHECK MICROWAVE ASSEMBLY
C3.
Exhaust Adaptor (absent
on models shipped for
recirculation exhaust)
Back of
Microwave
Place the microwave in its upright position, with the
top of the unit facing up.
The microwave oven may be shipped assembled for
top exhaust (adaptor installed) or for recirculation
exhaust (adaptor absent).
If the microwave was shipped for recirculation
exhaust, skip to C5. If shipped for top exhaust,
proceed with C4.
1
2