GE PB975 Range User Manual


 
3
Installation Instructions
PREPARE THE OPENING
See illustrations for all rough-in and spacing
dimensions.
The range may be placed with 0” clearance
(flush) at the back wall and side walls of
the cabinet.
NOTE: Use a 4 power cord to prevent
interference. Power cords 4
1
2 to 6 long
may have to be dressed to allow for
proper installation.
MINIMUM DIMENSIONS BETWEEN COOKTOP,
WALLS AND ABOVE THE COOKTOP:
*** Make sure the wall covering, countertop,
flooring and cabinets around the range
can withstand the heat (up to 200°F)
generated by the range.
*** Allow 30” minimum clearance between
surface units and bottom of unprotected
wood or metal cabinet, and 15” minimum
between countertop and adjacent cabinet
bottom.
*** Recommended spacing to heat-sensitive
surfaces.
2
3
1
4
3
1
4
7
3
4
23
1
2
47”
30”
Acceptable electrical
outlet area.
Orient the electrical
receptacle so the length
is parallel to the floor.
*0”
**15” Min.
**30” Min.
*0”
***6”
Min.
25
3
8
45”
36”