GE SCA1001HSS Oven User Manual


 
Specification Revised 4/04
240436
TM
SCA1001HSS – Advantium
®
120 Above-the-Cooktop Oven
Hood Exhaust Duct
Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.
EXHAUST CONNECTION:
The hood exhaust has been designed to mate with a standard 3-1/4” x 10”
rectangular duct.
If a round duct is required, a rectangular-to-round transition adaptor must be used.
Do not use less than a 6” diameter duct.
REAR EXHAUST:
If a rear or horizontal exhaust is to be used, care should be taken to align exhaust
with the space between studs, or wall should be prepared at the time it is constructed
by leaving enough space between the wall studs to accommodate exhaust.
Duct Equivalent
A. Rectangular-To-Round 5 Ft.
Transition Adaptor
B. Wall Cap 40 Ft.
C. 90° Elbow 10 Ft.
D. 45° Elbow 5 Ft.
E. 90° Elbow 25 Ft.
F. 45° Elbow 5 Ft.
G. Roof Cap 24 Ft.
Grille
Filter Kit Accessory
Filter Kit
JX81A–Recirculating
Charcoal Filter Kit
To be used when
the Advantium oven
cannot be vented
to the outside.
MAXIMUM DUCT LENGTH:
For satisfactory air movement, the total duct length of 3-1/4” x 10”
rectangular or 6” diameter round duct should not exceed
140 equivalent feet.
ELBOWS, TRANSITIONS, WALL AND ROOF CAPS, etc., present additional
resistance to airflow and are equivalent to a section of straight duct
which is longer than their actual physical size. When calculating the
total duct length, add the equivalent length of all transitions and adaptors
plus the length of all straight duct sections. The chart below shows the
approximate feet of equivalent length of some typical ducts.
For answers to your Monogram
,
®
GE Profile
or
GE
®
appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center
®
service, 800.626.2000.