ZGU486NRPSS (Natural Gas)
ZGU486LRPSS (Liquid Propane)
GE Monogram
®
48" Professional Gas Rangetop with 6 Burners and Grill
Dimensions and Installation Information
Backsplash Accessories
The rangetop requires a 12" minimum clearance to a
vertical combustible surface at the rear. A backsplash
is required for installations with less than 12" clearance.
The following backsplash accessories are available, or a
custom, non-combustible backsplash can be used.
ZX12B48PSS, 12" backsplash
ZXADJB48PSS, 30"-36" adjustable-height backsplash with
warming shelf
Side View with a Backsplash
Advance Planning for 48"
Professional Rangetops
Professional rangetops offer a number of choices in size and
rangetop configurations.
All Professional rangetops are factory set for natural or
liquid propane gas. The correct model should be ordered
for the installation situation.
Note: Conversion kits are included with the rangetop if the
wrong gas type was ordered. High Altitude kit, WB28K10553,
is also available. The kits must be installed by a qualified
service technician at additional cost.
Electrical Requirements
Rangetops must be supplied with 120V, 60Hz, and
connected to an individual, properly grounded branch circuit
protected by a 15 amp circuit breaker or time-delay fuse.
Gas Supply
Natural gas models are designed to operate at 5" water
column pressure. For proper operation, the pressure of the
natural gas supplied to the regulator must be between 7”
and 13” water column.
The liquid propane models are designed to operate at 10"
water column pressure. For proper operation, the pressure
of the LP source to the regulator must be between 11” and