GE Monogram Professional Rangetop Range User Manual


 
4
PRODUCT DIMENSIONS AND CLEARANCES FOR 48” MODELS
Design Information
27-1/2” to
Front of
Bullnose
8-1/2”
Height
22-3/4” Min.
2-1/2”
8”
7/8”
605Dia76
Universal Utility Locations
2”
1
7”
1
6”
L
ocate gas
inlet on back
wall or on
floor 2” from
back wall.
12” Minimum
Each Side
46-1/4”
48” Min. to
Combustibles
12” Minimum to
Combustibles or 0” to
non-combustible material
above the cooking sur
face
0”
Clearance
ADDITIONAL CLEARANCES:
Allow 12" minimum clearance to an adjacent wall on
each side.
Working areas adjacent to the rangetop should have
18" minimum clearance between countertop and the
bottom of the w
all cabinet
.
* The opening betw
een a 4” high backsplash must be 48”
to allow the rangetop to slide back against the wall.
13” Max.
18” Min.
48” Minimum
to Combustibles
12” Minimum to
Adjacent Wall
4
7-7/8
W
idth
WARNING:
Installations without a hood
require 48
"
minimum to combustibles
above the rangetop. A custom hood
installation with exposed horizontal
combustible surfaces must have
an Auto-On feature. Refer to hood
installation instructions for specific
hood clearances.
The surface of the entire back wall
above the countertop and below
the hood must be covered with
a non-combustible material such
as metal, ceramic tile, brick, marble
or other stone.
*48”
Non-combustible
material
48”