GE Monogram ZDIW50 Ice Maker User Manual


 
15
Vacation and Moving
To shut down the icemaker:
1. Disconnect the electrical power supply to the
icemaker and turn the Cycle Control Knob to “OFF.”
2. Remove all ice from the storage bin.
3. Shut off the water supply.
4. Remove the screw from the top of the lower access
panel and the two screws from the grille area of the
lower access panel, then remove the panel. Pull
forward at the bottom, then down.
5. Disconnect the inlet and outlet lines to the water
valve. Allow these lines to drain and then reconnect
to the valve.
6. Replace the lower access panel and screws. The
top of the access panel needs to be secured under
the two metal tabs before replacing the screws.
7. Remove water from the drain lines and drain
water pan.
8. Before using again, clean the icemaker and
storage bin.
NOTE: All components of the icemaker are
permanently lubricated at the factory. They should
not require any additional oiling throughout the
normal life of the machine.
NORMAL
THICK
THIN
ICE
ON
CLEAN
OFF
CYCLE
WARNING: Make sure the icemaker is
disconnected from the main power supply
before removing the lower access panel.
Failure to do so could result in electric
shock or personal injury.
Lower
Access
Panel
Grille
Area
Screw
Outlet
Inlet
Screws
Water
Pan