The range requires a 12" minimum clearance to a vertical combustible
surface at the rear. A backsplash is required for installations with
less than 12" clearance. The following backsplash accessories are
available, or a custom, non-combustible backsplash can be used.
Backsplashes: Order one with a 36"-wide range
ZX12B36HSS–12" backsplash
ZX22B36HSS– 22" backsplash with warming shelf
Backsplash with Warming Shelf
All Monogram Professional Wall-Mounted Hoods feature infrared
warming lights. The 22"-high warming shelf is a perfect complement
when installed with the tapered or straight-sided hoods.
If you choose to install this range with a Restaurant-Style
Professional Hood (ZV36RSFSS), no additional accessories are
required. These hoods are shipped with a stainless steel
backsplash and warming shelf.
Side View with a Backsplash
Electrical Requirements
Ranges must be supplied with 208/240V, 60Hz, and connected to
an individual, properly grounded branch circuit protected by a circuit
breaker or time-delay fuse. Install a 30-amp circuit for 36" ranges. The
receptacle must be a NEMA 14-50R device to accept the four-prong
plug on the range.
ZDP36N4DHSS (Natural Gas)
ZDP36L4DHSS (Liquid Propane)GE Monogram 36" Dual Fuel Professional Range with
4 Burners and Griddle
For answers to your Monogram,
®
GE Profile
or
GE
®
appliance questions, visit our website at
GEAppliances.com or call GE Answer Center
®
service, 800.626.2000.
Listed by
Underwriters
Laboratories
Backguard
36" Min.
to
Combustibles
0" Clearance
12" Min. to Combustibles or
0" Min. to Combustibles
with 12" or 22" Backsplash
Gas Supply
• Natural gas models are designed to operate at 5" water column
pressure. A regulator is required at the natural gas source to
provide maximum of 7" water pressure to the range regulator.
• The liquid propane models are designed to operate at 10" water
column pressure. A regulator is required at the LP source to provide
maximum of 14" water pressure to the range regulator.
4"
4"
4"
12"
12"
Gas
Supply
36"
1-1/2"
4"
Electric
Supply
Locate gas and
electric as shown
Specification Revised 3/08