GE Monogram ZET857WYWW Oven User Manual


 
10
Installation
30" Built-In Convection Ovens
208V
Electrical
supply
CAUTION
WARNING
These ovens are pre-wired for connec-
tion to 240 volt, 60 Hz., supply. If connecting
to a 208 volt supply, modifications must be made.
If connecting to a 208 volt, 60 Hz., supply, a jumper
must be used across two terminals.
• For double ovens, there are two jumpers, one for the
upper oven, one for the lower oven.
• For single ovens there is one jumper.
Single ovens,
double ovens–
(upper oven)
Double ovens–
(lower oven)
Double ovens–Lower
To connect to 208 volt circuit:
• Remove the access panel(s) located on the back of
the ovens.
• Loosen the first and second screws in the terminal
block as shown.
• Remove the jumper and place between the first and
second screws, tighten the screws to hold the
jumper in place.
• Replace the access panel(s).
Jumper
Loosen Screws
Jumper
Tighten Screws
1
2
3
4
5
Loosen Screws
Jumper
1
2
3
4
Loosen Screws
Jumper
Jumper
Loosen Screws
Jumper
Tighten Screws